Methacrylic Acid, Inhibited Chemical Storage Specifications

Compliant storage and rental solutions for Methacrylic Acid, Inhibited (C4H602). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Methacrylic Acid, Inhibited

used in making plastic sheets, moldings, fibers, resins, and other organic chemicals

Structured hazard data

Hazard class
Flammable liquids Category 4
Storage category
Flammable Storage
Flammable
Yes
Flash point
76 °C / 168.8 °F
Storage temperature
<59 F
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Strong oxidizing agents

Acute oral toxicity Category 4 Acute dermal toxicity Category 3 Acute Inhalation Toxicity - Vapors Category 4 Skin Corrosion/Irritation Category 1 A Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. F

Fire Suppression System

Dry Chemical fire suppression is recommended for Methacrylic Acid, Inhibited

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Methacrylic Acid, inhibited (C4H602). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: CO 2, dry chemical, dry sand, alcohol-resistant foam. Water mist may be usedtocool closed containers.

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Methacrylic Acid, inhibited should account for its listed hazards (Flammable liquids Category 4), climate control needs (<59 F), and segregation requirements. Strong oxidizing agents

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Physical State Liquid Appearance Colorless Odor Rotten-egg like Odor Threshold 10 ppm pH 2-2.2 100 g/L aq.sol Melting Point/Range 16 °C / 60.8 °F Boiling Point/Range 163 °C / 325.4 °F @ 760 mmHg Flash Point 76 °C / 168.8 °F

Matched to this chemical

Recommended storage solutions for Methacrylic Acid, Inhibited

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Methacrylic Acid, inhibited be stored?

Store Methacrylic Acid, inhibited in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable liquids Category 4). Climate range guidance: <59 F. Compatibility notes: Strong oxidizing agents US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Methacrylic Acid, inhibited flammable?

Yes — Methacrylic Acid, inhibited is flagged as a flammable hazard in this database (Yes). Flash point: 76 °C / 168.8 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Methacrylic Acid, inhibited?

Methacrylic Acid, inhibited is listed as: Flammable liquids Category 4. Acute oral toxicity Category 4 Acute dermal toxicity Category 3 Acute Inhalation Toxicity - Vapors Category 4 Skin Corrosion/Irritation Category 1 A Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. F

What fire suppression is recommended for Methacrylic Acid, inhibited?

Dry Chemical fire suppression is generally recommended for Methacrylic Acid, inhibited (C4H602). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Methacrylic Acid, inhibited storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Methacrylic Acid, inhibited. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.